System Outline
All processes on this equipment are completely automated from work ejection, measurement, judgment, sorting, to non defective product storage
1 hour of unattended operation is possible.
For measurement, a 0.1μm resolution non contact detector is adopted with repetition accuracy of 1μm making it possible for high precision measurement.
Also measurement data is processed using a 32 bit CPU, cycle time per piece is only 3.5 seconds.
Data can be saved in a file. It can be used for process capacity statistics management and can also be printed out.
Specification Outline
Power | AC100V 50/60Hz About 1.5KVA |
Air Supply | 0.4MPa (4kg/cm2) or more compressed air |
Measurement Item | Lenght Measurement (L) Squareness Measurement Parallellism Measurement Thickness Measurement (t) Thickness Parallellism |
Repetition Accuracy | 1μm |
Cycle Time | 3.5 seconds (Including stocker automatic exchange time) |
Unattended Operation Time | 1 Hour |
Work change | 3 Types |
Work Measurement | Thickness Measurement 3~4.5mm Lenght Measurement 20~42mm Width Measurement 15~25mm |